• Image
    Water Cooled Chiller Plant
    Supply,Install,Connect & Start Up of Water Cooled Chillers complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Cooling Tower
    Supply,Install,Connect & Start Up of Cooling Tower complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Air Cooled Chiller Plant
    Supply,Install,Connect & Start Up of Air Cooled Chillers complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Chilled Water Station
    Supply,Install,Connect & Start Up of Chilled Water Pumps complete with all accessories, fittings,control panels , anti-vibration pads & electrical connection as per International Norms
  • Image
    Air Handling Units
    Supply,Install,Connect & Start Up of Air Handling Units (Single & Modular) complete with all accessories, fittings,control panels & electrical connection as per International Norms.
  • Image
    Air Terminal Units
    Supply,Install,Connect & Start Up of Air Terminal Units (Fan Coil Units & Blower Coil Units) complete with all accessories, duct & hydronic connections
  • Image
    DX (Direct Expansion) System
    Supply,Install,Connect & Start Up of DX (Direct Expansion) System complete with Indoor Units (Wall Type, Cassette Type, Concealed Type, Floor type, ... ) & Outdoor Units. Packaged Roof Top Units are also available
  • Image
    VRF (Variable Refrigerant Flow) System
    Supply,Install,Connect & Start Up of VRF (Variable Refrigerant Flow) System complete with Indoor Units (Wall Type, Cassette Type, Concealed Type, Floor type, ... ) & Outdoor Units. VRF System is suitable for Residential, Commercial & Hospitality applications
  • Image
    Ductwork
    Supply,Install & Pressure Test of Ductwork covering all Pressure & Velocity Classes (Low,Medium & High) consisting of Flange Type or Drive / Hemmed Slip Type. Ductwork is constructed & installed as per SMACNA
  • Image
    Insulation & Jacketing
    Supply & Apply Fiberglass, Rock wool or Cross-linked Polyolefin Foam Lagging to Hydronic Piping to ensure thermal & acoustic insulation. An external Jacketing (St.St. , Aluminum or Resin) is applied later to protect against Mechanical & Weather Impact
  • Image
    Cold Rooms & Freezers
    Supply,Install & Start-Up Cold Rooms & Freezers complete with all accessories & control
  • Image
    Air Outlets
    Supply & Install as per SMACNA all types of Air Outlets such as but not limited to : Linear Bar Diffuser, Linear Slot Diffuser, Linear Flow Bar, Ceiling Diffuser, Jet Nozzles, Door Grilles,... All RAL Colors are available to satisfy the Interior Designer requirement
  • Image
    Control Dampers
    Supply & Install as per SMACNA all types of Air Control Dampers, Fire Dampers & Motorized Fire Smoke Dampers to fulfill Air Balancing , Fire Protection & Smoke Management Scenario
  • Image
    Sound Attenuators
    Design, Supply & Install as per SMACNA all types of Sound Attenuators on the Supply & Return Ducts to hit the required Sound Level inside the served area
  • Image
    Under Flooring Cooling System
    Supply,Install,Connect & Start Up of Under Flooring Cooling System complete with Tubing, Mat, Light Weight Concrete, Mixing Valves & Panels
  • Image
    Bio-Clean Duct De-Greasing System
    Supply,Install,Connect & Start Up of Bio-Clean Duct Degreasing System which continuously cleans and degreases kitchen exhaust air and ventilation systems. The process is done without any manual operation and neutralizes odors at the outlet of ducts. The system can incorporate the biodegradation of greases and fats in grease traps as well as keeping piping continuously clean and odorless
  • Image
    Axial Fans
    Supply,Install,Connect & Start Up of all Types of Axial Fans (Propeller, Tub Axial, Vane Axial & Inline ) complete with all accessories,control panels & electrical connection as per International Norms
  • Image
    Centrifugal Fans
    Supply,Install,Connect & Start Up of all Types of Centrifugal Fans (Forward Curved, Radial Blade, Backward Inclined, Airfoil Blade & Radial Tip) complete with all accessories,control panels & electrical connection as per International Norms
  • Image
    Mixed Flow Fans
    Supply,Install,Connect & Start Up of all sizes of Mixed Flow Fans complete with all accessories ,control panels & electrical connection as per International Norms
  • Image
    Induction Fans
    Supply,Install,Connect & Start Up of all sizes of Induction Fans complete with all accessories ,control panels & electrical connection as per International Norms.A Computational Fluid Dynamics (CFD) is also provided to ensure performance of IF inside parkings & tunnels.
  • Image
    Rooftop Fans
    Supply,Install,Connect & Start Up of all sizes of Rooftop Fans for Kitchen Exhaust & Smoke Extraction Applications complete with all accessories ,control panels & electrical connection as per International Norms.
  • Image
    Steam Boilers
    Supply,Install,Connect & Start Up of Steam Boilers (Fire Tube & Water Tube Types) complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
  • Image
    Hot Water Boilers
    Supply,Install,Connect & Start Up of Hot Water Boilers (Gas & Fuel, Condensing & Conventional) complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
  • Image
    Hot Water Storage Tanks
    Supply,Install,Connect & Start Up of Hot Water Storage Tanks complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
  • Image
    Solar Heating System
    Supply,Install,Connect & Start Up of Solar Heating System complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
  • Image
    Heat Exchangers
    Supply,Install,Connect & Start Up of Heat Exchangers (Plate Type & Shell/Tube Type) complete with all accessories & connections as per ASME Codes. HEX used for High Rise Building Hydronic System Application
  • Image
    Under Flooring Heating System
    Supply,Install,Connect & Start Up of Under Flooring Heating System complete with Tubing, Mat, Light Weight Concrete, Mixing Valve & Panels
  • Image
    Radiators & Towel Warmers
    Supply,Install,Connect Radiators (Cast Iron & Aluminum Types) & Towel Warmers complete with all accessories & thermostatic valve
  • Image
    Pump Station
    Supply,Install,Connect & Start Up of all types of Pumps (Transfer Pumps, Booster Sets) complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Well Pumps
    Supply,Install,Connect & Start Up of Well Pumps complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Submersible Pump
    Supply,Install,Connect & Start Up of Submersible Pumps complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    Water Supply System
    Supply, Install, Connect & Pressure Test of Water Supply Network covering Cold, Hot & Potable Water made of PPVC, PPR, GSP, Copper,...
  • Image
    Drainage System
    Supply, Install, Connect & Pressure Test Drainage Pipe covering Soil, Waste & Rain Water Utilities made of UPVC, PPVC, Cast Iron, HDPE, ...
  • Image
    Sanitary Fixtures
    Supply, Install, Connect & Commissioning of Sanitary Fixtures including WC,Lavatory,Shower, Bathtub, Urinal, Kitchen Sink complete with Mixers, Angle Valve, Drainage Traps & all needed accessories
  • Image
    Irrigation System
    Supply, Install, Connect & Commissioning of Automatic Irrigation System complete with Sprinkler, Piping & Control Unit
  • Image
    Reverse Osmosis Plant
    Supply,Install,Connect & Start Up of Reverse Osmosis complete with all accessories, fittings,control panels & electrical connection.
  • Image
    Softening Plant
    Supply,Install,Connect & Start Up of Softeners complete with all accessories to remove calcium, magnesium, and certain other metal cations in hard water. The resulting soft water requires less soap for the same cleaning effort, as soap is not wasted mopping up calcium ions. Soft water also extends the lifetime of plumbing by reducing or eliminating scale build-up in pipes and fittings. Water softening is usually achieved using lime softening or ion-exchange resins.
  • Image
    Sand & Carbon Filters
    Supply,Install,Connect & Start Up of Water Treatment Plant consisting of Sand & Carbon Filters complete with all accessories to remove impurities & odor
  • Image
    Ultra Violet Sterilizer
    Supply,Install,Connect & Start Up of Ultra Violet Sterilizer complete with all accessories to kill germs & bacteria
  • Image
    Water Features
    Design & Execution of Indoor & Outdoor Water Features complete with accessories, lighting, control & plant room
  • Image
    Swimming Pools
    Design & Execution of Swimming Pools complete with all accessories, lighting, control & plant room
  • Image
    Fire Pump Room
    Supply,Install,Connect & Start Up of Fire Pumps complete with all accessories, fittings,control panels & electrical connection as per NFPA , APSAD or British Standard.
  • Image
    Wet Riser
    Supply,Install,Connect & Test of Fire Wet Riser made of GSP or BSP complete with all accessories, pipe rings, riser anchors as per NFPA.
  • Image
    Dry Riser
    Supply,Install,Connect & Test of Fire Dry Riser made of GSP complete with all accessories, pipe rings, riser anchors as per NFPA.
  • Image
    Landing Valves
    Supply,Install,Connect & Test of Landing Valves Chrome Finished, Brass finished or Red Painted. Landing Valves could be provided with Stainless Steel or Red Black Steel Cabinets if required. Installation details are as per NFPA.
  • Image
    Fire Hose Cabinet
    Supply,Install,Connect & Test of Fire Hose Cabinets Stainless Steel Finished or RAL painted as per Architectural Requirement. Two types of Hose Cabinets could be provided: Reel as per BS and APSAD or Rack as per NFPA. FHCs could be installed Exposed, Recessed or Semi-Recessed as per Architectural Decision.
  • Image
    Fire Sprinklers
    Supply,Install,Connect & Test of Fire Sprinklers (Pendent or Upright Type, Concealed Type, Horizontal Wall Type, Decorative Type, High Speed Screen Type & Rapid Response Type). In addition, Sprinkler Fire Bulb Temperature Rank is from 135F up to 286F
  • Image
    Siamese Connection
    The Fire Department Connection (FDC), also know as the Siamese Connection, is an important component found on most sprinkler and standpipe systems. When a sprinkler system,Hose or LV are activated, the fire department connects hose lines from a pumper truck to the fire department connection. This connection allows the fire department to supplement the fire protection system in the event of a fire.
  • Image
    Fire Zone Control Valve
    Supply,Install, Connect & Test of Zone Control Valve (FZCV) which control a zone area like sprinkler in one floor in building . ZCV components is consisting of butterfly valve and flow switch and pressure gauge and test and drain valve . When sprinkler open the water is flow from the zcv and flow switch make a signal to fire alarm control panel
  • Image
    FM200 Suppression System
    Supply, Install, Connect, Test & Cx of FM-200 Suppression System​ which are managing and protecting high-value assets, processes, and facilities. FM-200 systems are internationally accepted as providing reliable, effective, affordable fire protection solutions for applications found in telecommunication sites, data centers and archives, museums, oil and gas facilities, power plants, and more.
  • Image
    CO2 Suppression System
    Carbon dioxide or CO2 is a colorless, odorless, electrically non-conductive gas that is highly efficient as a fire suppression agent. Carbon Dioxide Fire Protection Systems use intelligent, reliable and fast-acting control panels to quickly sense a fire before it can cause damage to property. Carbon dioxide gas has a high rate of expansion, which allows a fire protection system to work fast. When applied to a fire, CO2 provides a heavy blanket of gas that reduces the oxygen level to a point where combustion cannot occur. Since carbon dioxide is a gas, there is no clean-up associated with a fire suppression system discharge. That means minimal interruption to your business. In fact, the cost of clean-up and peripheral damage associated with a water sprinkler systems, foam systems and dry chemical agents can exceed the costs associated with the actual fire damage. With a Carbon Dioxide system, clean-up costs and downtime associated with a CO2 discharge are negligible. CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B and C hazards.
  • Image
    Fire Extinguishers
    Supply & Install all types of Fire Extinguishers (ABC Dry Powder, CO2 and Pressurized Water) as per BS, APSAD or NFPA to protect occupied areas against fire event.
  • Image
    LPG Central Tanks
    Supply,Install,Connect & Commissioning of LPG Central Tanks complete with all accessories, fittings,control panels & electrical connection as per International Norms
  • Image
    First Stage Regulation Station
  • Image
    Second Stage Regulation Station
  • Image
    Gas Detection Station
  • Image
    LPG Cabinet
  • Image
    LPG Manifold
  • Image
    LPG Metering System
  • Image
    CAD 2D Drawings
    Design & Shop Drawings are elaborated thru CAD software by a Qualified Team of Engineers & Draftsmen
  • Image
    REVIT 3D Modeling
    3D Modeling are elaborated thru REVIT software by a Qualified Team of Engineers & Draftsmen