- Water Cooled Chiller PlantSupply,Install,Connect & Start Up of Water Cooled Chillers complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Cooling TowerSupply,Install,Connect & Start Up of Cooling Tower complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Air Cooled Chiller PlantSupply,Install,Connect & Start Up of Air Cooled Chillers complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Chilled Water StationSupply,Install,Connect & Start Up of Chilled Water Pumps complete with all accessories, fittings,control panels , anti-vibration pads & electrical connection as per International Norms
- Air Handling UnitsSupply,Install,Connect & Start Up of Air Handling Units (Single & Modular) complete with all accessories, fittings,control panels & electrical connection as per International Norms.
- Air Terminal UnitsSupply,Install,Connect & Start Up of Air Terminal Units (Fan Coil Units & Blower Coil Units) complete with all accessories, duct & hydronic connections
- DX (Direct Expansion) SystemSupply,Install,Connect & Start Up of DX (Direct Expansion) System complete with Indoor Units (Wall Type, Cassette Type, Concealed Type, Floor type, ... ) & Outdoor Units. Packaged Roof Top Units are also available
- VRF (Variable Refrigerant Flow) SystemSupply,Install,Connect & Start Up of VRF (Variable Refrigerant Flow) System complete with Indoor Units (Wall Type, Cassette Type, Concealed Type, Floor type, ... ) & Outdoor Units. VRF System is suitable for Residential, Commercial & Hospitality applications
- DuctworkSupply,Install & Pressure Test of Ductwork covering all Pressure & Velocity Classes (Low,Medium & High) consisting of Flange Type or Drive / Hemmed Slip Type. Ductwork is constructed & installed as per SMACNA
- Insulation & JacketingSupply & Apply Fiberglass, Rock wool or Cross-linked Polyolefin Foam Lagging to Hydronic Piping to ensure thermal & acoustic insulation. An external Jacketing (St.St. , Aluminum or Resin) is applied later to protect against Mechanical & Weather Impact
- Cold Rooms & FreezersSupply,Install & Start-Up Cold Rooms & Freezers complete with all accessories & control
- Air OutletsSupply & Install as per SMACNA all types of Air Outlets such as but not limited to : Linear Bar Diffuser, Linear Slot Diffuser, Linear Flow Bar, Ceiling Diffuser, Jet Nozzles, Door Grilles,... All RAL Colors are available to satisfy the Interior Designer requirement
- Control DampersSupply & Install as per SMACNA all types of Air Control Dampers, Fire Dampers & Motorized Fire Smoke Dampers to fulfill Air Balancing , Fire Protection & Smoke Management Scenario
- Sound AttenuatorsDesign, Supply & Install as per SMACNA all types of Sound Attenuators on the Supply & Return Ducts to hit the required Sound Level inside the served area
- Under Flooring Cooling SystemSupply,Install,Connect & Start Up of Under Flooring Cooling System complete with Tubing, Mat, Light Weight Concrete, Mixing Valves & Panels
- Bio-Clean Duct De-Greasing SystemSupply,Install,Connect & Start Up of Bio-Clean Duct Degreasing System which continuously cleans and degreases kitchen exhaust air and ventilation systems. The process is done without any manual operation and neutralizes odors at the outlet of ducts. The system can incorporate the biodegradation of greases and fats in grease traps as well as keeping piping continuously clean and odorless
- Axial FansSupply,Install,Connect & Start Up of all Types of Axial Fans (Propeller, Tub Axial, Vane Axial & Inline ) complete with all accessories,control panels & electrical connection as per International Norms
- Centrifugal FansSupply,Install,Connect & Start Up of all Types of Centrifugal Fans (Forward Curved, Radial Blade, Backward Inclined, Airfoil Blade & Radial Tip) complete with all accessories,control panels & electrical connection as per International Norms
- Mixed Flow FansSupply,Install,Connect & Start Up of all sizes of Mixed Flow Fans complete with all accessories ,control panels & electrical connection as per International Norms
- Induction FansSupply,Install,Connect & Start Up of all sizes of Induction Fans complete with all accessories ,control panels & electrical connection as per International Norms.A Computational Fluid Dynamics (CFD) is also provided to ensure performance of IF inside parkings & tunnels.
- Rooftop FansSupply,Install,Connect & Start Up of all sizes of Rooftop Fans for Kitchen Exhaust & Smoke Extraction Applications complete with all accessories ,control panels & electrical connection as per International Norms.
- Steam BoilersSupply,Install,Connect & Start Up of Steam Boilers (Fire Tube & Water Tube Types) complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
- Hot Water BoilersSupply,Install,Connect & Start Up of Hot Water Boilers (Gas & Fuel, Condensing & Conventional) complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
- Hot Water Storage TanksSupply,Install,Connect & Start Up of Hot Water Storage Tanks complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
- Solar Heating SystemSupply,Install,Connect & Start Up of Solar Heating System complete with all accessories, fittings,safety kits, control panels & electrical connection as per International Norms.
- Heat ExchangersSupply,Install,Connect & Start Up of Heat Exchangers (Plate Type & Shell/Tube Type) complete with all accessories & connections as per ASME Codes. HEX used for High Rise Building Hydronic System Application
- Under Flooring Heating SystemSupply,Install,Connect & Start Up of Under Flooring Heating System complete with Tubing, Mat, Light Weight Concrete, Mixing Valve & Panels
- Radiators & Towel WarmersSupply,Install,Connect Radiators (Cast Iron & Aluminum Types) & Towel Warmers complete with all accessories & thermostatic valve
- Pump StationSupply,Install,Connect & Start Up of all types of Pumps (Transfer Pumps, Booster Sets) complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Well PumpsSupply,Install,Connect & Start Up of Well Pumps complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Submersible PumpSupply,Install,Connect & Start Up of Submersible Pumps complete with all accessories, fittings,control panels & electrical connection as per International Norms
- Water Supply SystemSupply, Install, Connect & Pressure Test of Water Supply Network covering Cold, Hot & Potable Water made of PPVC, PPR, GSP, Copper,...
- Drainage SystemSupply, Install, Connect & Pressure Test Drainage Pipe covering Soil, Waste & Rain Water Utilities made of UPVC, PPVC, Cast Iron, HDPE, ...
- Sanitary FixturesSupply, Install, Connect & Commissioning of Sanitary Fixtures including WC,Lavatory,Shower, Bathtub, Urinal, Kitchen Sink complete with Mixers, Angle Valve, Drainage Traps & all needed accessories
- Irrigation SystemSupply, Install, Connect & Commissioning of Automatic Irrigation System complete with Sprinkler, Piping & Control Unit
- Reverse Osmosis PlantSupply,Install,Connect & Start Up of Reverse Osmosis complete with all accessories, fittings,control panels & electrical connection.
- Softening PlantSupply,Install,Connect & Start Up of Softeners complete with all accessories to remove calcium, magnesium, and certain other metal cations in hard water. The resulting soft water requires less soap for the same cleaning effort, as soap is not wasted mopping up calcium ions. Soft water also extends the lifetime of plumbing by reducing or eliminating scale build-up in pipes and fittings. Water softening is usually achieved using lime softening or ion-exchange resins.
- Sand & Carbon FiltersSupply,Install,Connect & Start Up of Water Treatment Plant consisting of Sand & Carbon Filters complete with all accessories to remove impurities & odor
- Ultra Violet SterilizerSupply,Install,Connect & Start Up of Ultra Violet Sterilizer complete with all accessories to kill germs & bacteria
- Water FeaturesDesign & Execution of Indoor & Outdoor Water Features complete with accessories, lighting, control & plant room
- Swimming PoolsDesign & Execution of Swimming Pools complete with all accessories, lighting, control & plant room
- Fire Pump RoomSupply,Install,Connect & Start Up of Fire Pumps complete with all accessories, fittings,control panels & electrical connection as per NFPA , APSAD or British Standard.
- Wet RiserSupply,Install,Connect & Test of Fire Wet Riser made of GSP or BSP complete with all accessories, pipe rings, riser anchors as per NFPA.
- Dry RiserSupply,Install,Connect & Test of Fire Dry Riser made of GSP complete with all accessories, pipe rings, riser anchors as per NFPA.
- Landing ValvesSupply,Install,Connect & Test of Landing Valves Chrome Finished, Brass finished or Red Painted. Landing Valves could be provided with Stainless Steel or Red Black Steel Cabinets if required. Installation details are as per NFPA.
- Fire Hose CabinetSupply,Install,Connect & Test of Fire Hose Cabinets Stainless Steel Finished or RAL painted as per Architectural Requirement. Two types of Hose Cabinets could be provided: Reel as per BS and APSAD or Rack as per NFPA. FHCs could be installed Exposed, Recessed or Semi-Recessed as per Architectural Decision.
- Fire SprinklersSupply,Install,Connect & Test of Fire Sprinklers (Pendent or Upright Type, Concealed Type, Horizontal Wall Type, Decorative Type, High Speed Screen Type & Rapid Response Type). In addition, Sprinkler Fire Bulb Temperature Rank is from 135F up to 286F
- Siamese ConnectionThe Fire Department Connection (FDC), also know as the Siamese Connection, is an important component found on most sprinkler and standpipe systems. When a sprinkler system,Hose or LV are activated, the fire department connects hose lines from a pumper truck to the fire department connection. This connection allows the fire department to supplement the fire protection system in the event of a fire.
- Fire Zone Control ValveSupply,Install, Connect & Test of Zone Control Valve (FZCV) which control a zone area like sprinkler in one floor in building . ZCV components is consisting of butterfly valve and flow switch and pressure gauge and test and drain valve . When sprinkler open the water is flow from the zcv and flow switch make a signal to fire alarm control panel
- FM200 Suppression SystemSupply, Install, Connect, Test & Cx of FM-200 Suppression System which are managing and protecting high-value assets, processes, and facilities. FM-200 systems are internationally accepted as providing reliable, effective, affordable fire protection solutions for applications found in telecommunication sites, data centers and archives, museums, oil and gas facilities, power plants, and more.
- CO2 Suppression SystemCarbon dioxide or CO2 is a colorless, odorless, electrically non-conductive gas that is highly efficient as a fire suppression agent. Carbon Dioxide Fire Protection Systems use intelligent, reliable and fast-acting control panels to quickly sense a fire before it can cause damage to property. Carbon dioxide gas has a high rate of expansion, which allows a fire protection system to work fast. When applied to a fire, CO2 provides a heavy blanket of gas that reduces the oxygen level to a point where combustion cannot occur. Since carbon dioxide is a gas, there is no clean-up associated with a fire suppression system discharge. That means minimal interruption to your business. In fact, the cost of clean-up and peripheral damage associated with a water sprinkler systems, foam systems and dry chemical agents can exceed the costs associated with the actual fire damage. With a Carbon Dioxide system, clean-up costs and downtime associated with a CO2 discharge are negligible. CO2 fire suppression system is extremely versatile and effective on a wide range of flammable and combustible materials and approved for Class A, B and C hazards.
- Fire ExtinguishersSupply & Install all types of Fire Extinguishers (ABC Dry Powder, CO2 and Pressurized Water) as per BS, APSAD or NFPA to protect occupied areas against fire event.
- LPG Central TanksSupply,Install,Connect & Commissioning of LPG Central Tanks complete with all accessories, fittings,control panels & electrical connection as per International Norms
- First Stage Regulation Station
- Second Stage Regulation Station
- Gas Detection Station
- LPG Cabinet
- LPG Manifold
- LPG Metering System